What is ATH and How Does It Work?
Aluminum Trihydrate (ATH, Al(OH)₃) is the workhorse of halogen-free flame retardants. When heated above ~200°C, ATH decomposes endothermically, releasing water vapor:
2Al(OH)₃ → Al₂O₃ + 3H₂O (absorbs ~1.2 kJ/g)
This reaction simultaneously: (1) absorbs heat from the polymer, (2) dilutes flammable gases with water vapor, and (3) leaves a protective alumina char layer that blocks heat and oxygen. No toxic halogen gas is produced — that's why ATH is the global default for low-smoke zero-halogen (LSZH) compounds.
Key Applications
1. Wire & Cable Compounds
The #1 use of ATH. LSZH cable sheathing compounds typically load 60–65 wt% ATH. Required for building wiring, subway tunnels, data centers, and offshore wind cables where fire smoke toxicity is life-critical.
2. Engineered Plastics & SMC/BMC
Polypropylene, PVC, and unsaturated polyester BMC/SMC use ATH for electrical enclosures, automotive parts, and electrical insulators. Typical loading: 40–60 wt%.
3. Coatings & Paints
Intumescent and fire-retardant coatings use fine ATH (D50 < 2 µm) as a cost-effective smoke suppressant and char former.
4. Composites
Polyester and epoxy composites for bathroom fixtures, automotive interiors, and construction panels use ATH for flame spread classification.
Loading Levels and Trade-offs
| Application | Typical ATH Loading | Notes |
|---|---|---|
| LSZH cable jacket | 60–65% | Maximum for UL94 V-0 / low smoke |
| PVC cable compound | 30–50% | Combined with antimony oxide |
| SMC/BMC | 50–65% | Improves arc tracking resistance |
| Coatings | 20–40% | Use ultra-fine grade |
Surface Treatment Matters
Raw ATH is hydrophilic and poorly disperses in non-polar polymers. For best mechanical and electrical performance:
- Silane treatment (vinyl, amino, epoxy silanes): Improves dispersion and impact strength
- Fatty acid treatment: Cost-effective for PVC and rubber systems
- Untreated grade: Acceptable for water-based systems and epoxy
Why Choose ATH Over Halogenated FR?
- ✅ No dioxins, no HCl/HBr, low smoke density
- ✅ Lower cost than brominated FR + antimony oxide systems at high loading
- ✅ Meets RoHS, REACH, and EU construction product regulations (CPR)
- ✅ Dual function: flame retardant and filler — reduces compound cost
Maylynk supplies ATH in multiple grades (uncoated, silane-coated, various particle sizes) for cable, plastic, and coating applications. Contact our sales team for grade recommendations and free samples.