수산화알루미늄(ATH) 난연 충전재: 응용 분야와 장점

What is ATH and How Does It Work?

Aluminum Trihydrate (ATH, Al(OH)₃) is the workhorse of halogen-free flame retardants. When heated above ~200°C, ATH decomposes endothermically, releasing water vapor:

2Al(OH)₃ → Al₂O₃ + 3H₂O (absorbs ~1.2 kJ/g)

This reaction simultaneously: (1) absorbs heat from the polymer, (2) dilutes flammable gases with water vapor, and (3) leaves a protective alumina char layer that blocks heat and oxygen. No toxic halogen gas is produced — that's why ATH is the global default for low-smoke zero-halogen (LSZH) compounds.

Key Applications

1. Wire & Cable Compounds

The #1 use of ATH. LSZH cable sheathing compounds typically load 60–65 wt% ATH. Required for building wiring, subway tunnels, data centers, and offshore wind cables where fire smoke toxicity is life-critical.

2. Engineered Plastics & SMC/BMC

Polypropylene, PVC, and unsaturated polyester BMC/SMC use ATH for electrical enclosures, automotive parts, and electrical insulators. Typical loading: 40–60 wt%.

3. Coatings & Paints

Intumescent and fire-retardant coatings use fine ATH (D50 < 2 µm) as a cost-effective smoke suppressant and char former.

4. Composites

Polyester and epoxy composites for bathroom fixtures, automotive interiors, and construction panels use ATH for flame spread classification.

Loading Levels and Trade-offs

ApplicationTypical ATH LoadingNotes
LSZH cable jacket60–65%Maximum for UL94 V-0 / low smoke
PVC cable compound30–50%Combined with antimony oxide
SMC/BMC50–65%Improves arc tracking resistance
Coatings20–40%Use ultra-fine grade

Surface Treatment Matters

Raw ATH is hydrophilic and poorly disperses in non-polar polymers. For best mechanical and electrical performance:

  • Silane treatment (vinyl, amino, epoxy silanes): Improves dispersion and impact strength
  • Fatty acid treatment: Cost-effective for PVC and rubber systems
  • Untreated grade: Acceptable for water-based systems and epoxy

Why Choose ATH Over Halogenated FR?

  • ✅ No dioxins, no HCl/HBr, low smoke density
  • ✅ Lower cost than brominated FR + antimony oxide systems at high loading
  • ✅ Meets RoHS, REACH, and EU construction product regulations (CPR)
  • ✅ Dual function: flame retardant and filler — reduces compound cost

Maylynk supplies ATH in multiple grades (uncoated, silane-coated, various particle sizes) for cable, plastic, and coating applications. Contact our sales team for grade recommendations and free samples.